    There are also some problems that cannot be avoided during the operation of heat-conducting oil boilers. These problems are caused by different factors. The more common ones are overheating of the oil, excessive noise, internal leakage, and so on.Here we need to figure out the causes of these common problems in heat-conducting oil boilers.

 


    The oil temperature in the heat-conducting oil boiler is required, generally it needs to reach 200 degrees or more, but it cannot exceed 500 degrees.Once the oil temperature is too high, it will cause the quality of the heat transfer oil to decrease, and it may also damage the seals between the boiler components, causing the heat transfer oil boiler to leak or drive the physical consequences.


 


    The reason why the oil temperature of the heat-conducting oil boiler is too high may be caused by improper adjustment of the boiler components; of course, it may also be caused by the unreasonable operation and maintenance of the equipment. It is necessary to improve from the above aspects to make the heat-conducting oil boiler oil The temperature is kept within the normal range.


 


    When the heat-conducting oil boiler is working, if its parts become loose, it will inevitably produce a lot of noise.We can reasonably select parts for the boiler to eliminate the source of noise, and at the same time ensure the stability of the parts and avoid loosening.


 


    Once the heat-conducting oil boiler has an internal leakage problem, it will be manifested as a drop in operating pressure, and in serious cases, the movement speed of the components will even drop or creep.The leakage of the heat-conducting oil boiler is divided into two aspects: external leakage and internal leakage. The former can easily occur, but the latter needs to be determined by testing the pressure or flow rate.


 


    The leakage of heat conduction oil boiler is mostly caused by problems in the sealing system, but it may also be caused by damage to the component shell or pipeline. Therefore, maintenance personnel should understand the operating principles and application methods of various forms of sealing, and replace the seals in time .


 


    The internal leakage of the boiler is relatively complicated. Excessive fit clearance is the main reason for this problem. If you encounter similar problems, you need to replace the relevant components or parts, and can only be used after passing the test.